Re: REFLECTOR: sequence valve location
Paul,
> Have you activated your hydraulic pump yet to test your new sequence
> valve location in the bottom of the canard bulkhead? (V.V. 17:15)
> Did it help to smooth nose gear door closing and eliminate the main gear
> bounce? Still advise the location?
The "trick" to eliminating nose door slamming is to locate the sequence valve
as near to a linkage pivot point as possible. It takes an awful lot of force
to depress this valve, so the more leverage you can get, the better.
Dave Black